| Poor ventilation results in steam from bathrooms, showers and kitchens which creates condensation. |
A commercial extraction fan is designed to help with poor ventilation. Poor ventilation results in steam from bathrooms, showers and kitchens which creates condensation. The resulting damp conditions can lead to mould, peeling wallpaper and timber rot. Smells from kitchens, lavatories and tobacco smoke are unpleasant and unnecessary. Sealing doors and windows to conserve heat makes the situation worse by reducing natural ventilation. Installing an extractor fan overcomes these problems and is a relatively simple operation to carry out.
Building Regulations require the installation of mechanical ventilation in all kitchens, bathrooms and toilets.
There are two basic fan types to choose from:
Axial; these fans are designed to move air over short distances only, and are therefore suitable for window fixing or "through the wall" applications. They are not suitable for ducting runs in excess of 2 metres or in an exposed or high-rise position where wind can create extra resistance. If in doubt fit a centrifugal type.
Centrifugal; these fans are designed to move air over longer distances, and will perform well against the resistance presented by longer lengths of ducting. Traditionally fitted with higher specification motors, they also provide longer life.
SLC400 Elta Longcase FAN 400 x 400mm
|
![]() |
SLC450 Elta Longcase FAN 450 x 375mm
|
![]() |
SLC500 Elta Longcase FAN 500 x 400mm
|
![]() |
Eurofoil CA400 Shortcase FAN 400 x 190mm
|
![]() |
Eurofoil CA450 Shortcase FAN 450 x 190mm
|
![]() |
To select the correct fan:
The minimum number of air changes needed per hour is 10-15 for utility rooms, 10 for kitchens and 3 for living rooms. In bathrooms, showers and toilets, regulations require the fan to be fitted with a timer giving a 15 minute over-run after the room has been vacated. This is usually achieved by operating the extractor fan via the light switch.
Modern kitchen ventilation is achieved using a cooker hood, however on occasion extra ventilation is required.
Building regulations stipulate that you need a larger fan in kitchens.
While most bathroom fans have a 100mm spigot (the diameter of the air outlet on the back), kitchen fans tend to have a 150mm diameter spigot.
Fans can vent to the outside world in one of three ways - wall, window or ceiling. Not all fans can be mounted in all ways so it is always best to check which solution is best for your circumstances.
Eurofoil CA500 Shortcase FAN 500 x 250mm
|
![]() |
Turbo Prop Vent-axia 450
|
![]() |
Turbo Prop Vent-axia 500
|
![]() |
Fans need to have special attention paid to them when being installed.
In recognition of this, Part P of the Building Regulations came into effect in 2005 and covers the installation of electrical appliances in the home. It stipulates that the householder can undertake small replacement jobs such as electrical sockets or light switches but for places considered 'high risk' - e.g. wet rooms, such as bathrooms - special consideration must be given. A qualified electrician who is registered under the Part P self-certification scheme must carry out this electrical work.